After installing UAPM 11.3.4 with the ADT interface and the Prerequisite patch, QO99416, I cannot reinstall the UAPM/ADT interface. I am receiving the error, "Incorrect UAPM Version (11.03.0401) - version must be exactly 11.03.0400 in order to install..."
search cancel

After installing UAPM 11.3.4 with the ADT interface and the Prerequisite patch, QO99416, I cannot reinstall the UAPM/ADT interface. I am receiving the error, "Incorrect UAPM Version (11.03.0401) - version must be exactly 11.03.0400 in order to install..."

book

Article ID: 54297

calendar_today

Updated On:

Products

CA Automation Suite for Data Centers - Configuration Automation CA Client Automation - Asset Management CA Client Automation - IT Client Manager CA Client Automation CA Client Automation - Remote Control CA Client Automation - Asset Intelligence CA Client Automation - Desktop Migration Manager CA Client Automation - Patch Manager CA IT Asset Manager CA Software Asset Manager (CA SAM) ASSET PORTFOLIO MGMT- SERVER CA Service Management - Asset Portfolio Management CA Service Management - Service Desk Manager

Issue/Introduction

Description:

After installing UAPM 11.3.4 with the ADT interface and the Prerequisite patch, QO99416, I cannot reinstall the UAPM/ADT interface. I am receiving the error, "Incorrect UAPM Version (11.03.0401) - version must be exactly 11.03.0400 in order to install this product."

Solution:

IMPORTANT: This article contains information about modifying the registry.
Before you modify the registry, make sure to create back up of the registry and ensure that you understand how to restore the registry if a problem may occur.
For more information about how to back up, restore, and edit the registry, please review the relevant Microsoft Knowledge Base articles on support.microsoft.com.

The UAPM 11.3.4 prerequisite patch, QO99416 changes the version of UAPM stored in the Windows registry from 11.03.0400 to 11.03.0401. If you need to reinstall ADT after applying patch QO99416, you must first change the registry key containing the current version of UAPM to match the required version, perform the installation, then change the registry key back to it's original value.

Use the Window's regedit utility to view and modify the Windows registry. For instructions on using Regedit, refer to Regedit Help within the program.

The registry key to change is:

HKEY_LOCAL_MACHINE\software\computer associates\unicenter asset portfolio management

Change the data value from 11.03.0401 to 11.03.0400

Close regedit and perform the reinstallation of ADT, then use regedit to revert the key back to its original value.