CA Distributed Database Management CA Database Analyzer for DB2 for Oracle Database Analyzer (IMS Tools) Mainframe Configuration Manager for IMS for z/OS IMS TOOLS - MISC Compress Data Compression (IMS Tools) Database Analyzer for IMS for z/OS Database Copier for IMS for z/OS Database Organizer for IMS for z/OS Mainframe Extended Terminal Manager (IMS Tools) High Performance Recovery for IMS for z/OS Database Organizer (IMS Tools) Mainframe Program Restart Manager for IMS for z/OS Secondary Index Builder for IMS for z/OS Secondary Index for IMS for z/OS

Issue/Introduction

Description

Why can HPO batch job and/or the CA tools started task (STCITK) abend with the following messages and how can they be avoided?

HPO3000E LXCF ERROR,R15=00000806,R0=00000004,FUNCTION=INITIALISE
HPO0508E ERROR DURING XCF INITIALISATION

Solution

HPO (Full-function online reorg) uses the z/OS Cross-System Coupling Facility (XCF) to provide IMSPLEX support.

To enable this support the CA Common Services library must be used. Usually, this library is a part of the LINKLIST concatenation and, therefore, need not be allocated to the HPO batch job and STCITK job control.

If, however, the library is not in LINKLIST it must be added to the HPO batch job and STCITK JCL.

If this is not done both will abend with messages HPO3000E and HPO0508E.