Is there any way to display the status of a module initialized using CAS9/CAIRIM?
search cancel

Is there any way to display the status of a module initialized using CAS9/CAIRIM?

book

Article ID: 54105

calendar_today

Updated On:

Products

COMMON SERVICES FOR Z/OS 90S SERVICES COMMON PRODUCT SERVICES COMPONENT Common Services

Issue/Introduction

 

I ran CAS9 to load an initialization module specified in PARMLIB DD file, but it seems the module has not been initialized successfully... Is there any way to display the status of modules initialized using CAS9/CAIRIM?

 

 

Environment


Component: CAIRIM

Resolution

You can use CAIRIMU utility to display the status of all modules initialized using CAS9/CAIRIM. CAIRIMU lists the product or component name, version and level, and displays the result of each initialization program in the form of date, time, and success or failure indicated by the return code.

Generally, output from CAIRIMU will be as follows:

 CAS9006I THE FOLLOWING PRODUCTS HAVE BEEN INITIALIZED: 
 CAS9002I 
 CAS9007I PRODUCT             VERS      INIT   DATE/TIME 
 CAS9008I product             version   init   date time 
 . . . 
 CAS9009I INITIALIZED FROM loadlib 
 CAS9002I 
 CAS9010I NUMBER OF INTERFACES: nn 

Also, if CA LMP license management software has detected problems, the following output may appear when CAIRIMU is run:
CAS9012A nnnn License warnings/violations on CPU @@@@@@
CAS9013A Product %% expired and is still in use.

Refer to Administrator Guide for details on CAIRIMU utility.