Batch utility ZCEEVENT abends with S000 U1001.
search cancel

Batch utility ZCEEVENT abends with S000 U1001.

book

Article ID: 53846

calendar_today

Updated On:

Products

Alchemist TPX - Session Management Vman Session Management for z/OS

Issue/Introduction

ZCEEVENT STARTING                                
ZCELD04E - SR.UT{} SSCI ERROR: 001/0C010004 DURING FUNCTION: INITIALIZE      
IEA995I SYMPTOM DUMP OUTPUT  767                                             
  USER COMPLETION CODE=1001                                                  
 TIME=16.08.20  SEQ=00553  CPU=0000  ASID=01C5                               
 PSW AT TIME OF ERROR  078D1000   B6521AE8  ILC 2  INTC 0D                   
   ACTIVE LOAD MODULE           ADDRESS=365005E8  OFFSET=00021500            
   NAME=ZCEEVENT                                                             
   DATA AT PSW  36521AE2 - 00181610  0A0D4100  00014110                      
   AR/GR 0: B5362D16/80000000   1: 00000000/800003E9                         
         2: 00000000/00000000   3: 00000000/00000000                         
         4: 00000000/007D9D60   5: 00000000/007FF5E0                         
         6: 00000000/007BEFE0   7: 00000000/FD000000                         
         8: 00000000/007F8088   9: 00000000/007FF7A8                         
         A: 00000000/36525780   B: 00000000/365236C4                         
         C: 00000000/36521A18   D: 00000000/36525438                         
         E: 00000000/B6521ACC   F: 00000000/00000004                         
 END OF SYMPTOM DUMP                                                         
IEF450I SMITH99B STEP1 - ABEND=S000 U1001 REASON=00000000  768               
        TIME=16.08.20

 

Environment

Release:
Component: ALCMST

Resolution

ZCELD04E SR.UT{server-name}, SSCI ERROR: ssci-error-code DURING FUNCTION: INITIALIZE                                                           

SSCI ERROR: 001/0C... indicates Alchemist not started since last IPL.

Verify that:

  1. Alchemist is currently running, and
  2. The batch utility, ZCEEVENT is running on the same LPAR as the Alchemist started task.