0P24I C PROG CHECK SYS251=900 ... CCSW=0000627C6000200000 CCB=627C48 ... 0P73I I/O ERROR ... after drive was attached by DYNAMCMS!
search cancel

0P24I C PROG CHECK SYS251=900 ... CCSW=0000627C6000200000 CCB=627C48 ... 0P73I I/O ERROR ... after drive was attached by DYNAMCMS!

book

Article ID: 53468

calendar_today

Updated On:

Products

Dynam for VSE Dynam VSE Option

Issue/Introduction

On z/VSE 4.1 ... with interface to DYNAMCMS ... and IBM 3494 Robot
after drive was attached by DYNAMCMS we received:

F3 0014 0P24I C  PROG CHECK SYS251=900 
   CCSW=0000627C6000200000 CCB=627C48 
F3 0003 0P73I I/O ERROR 

 

 

Environment

Release: DYNAM.00400-2.3-CA-Dynam
Component:

Cause

An error of this kind may occur, if an error in the definition of the density for a tape dataset is made. 

The density associated with drive 900 (for example, '08M') has been removed (by mistake) from the catalog DSN entry !
The density defined in the catalog DSN entry does not match the density that can be written by drive 900 !
The VOLSER mounted on drive 900 has been initialized with the wrong density !

Resolution

Review the DSN catalog for either the missing and/or incorrect definition or the VOLSER intiailization for the type of drive and make the appropriate correction(s),