Getting ** ASMA142E OPERATION CODE NOT COMPLETE ON FIRST RECORD and ** ASMA140W END RECORD MISSING assembly errors in DBGDRIVx routine.
search cancel

Getting ** ASMA142E OPERATION CODE NOT COMPLETE ON FIRST RECORD and ** ASMA140W END RECORD MISSING assembly errors in DBGDRIVx routine.

book

Article ID: 53117

calendar_today

Updated On:

Products

APAS Insight Monitor for Adabas PLEU

Issue/Introduction

Description:

Getting the following errors when trying to assemble one of the DBG Driver modules - DBGDRIVC, DBGDRIVK, DBGDRIVT:

** ASMA142E OPERATION CODE NOT COMPLETE ON FIRST RECORD
** ASMA140W END RECORD MISSING

Solution:

Check the DBGDRIVx source member for a blank line after the END statement at the bottom of the source member. Delete the blank line and rerun the assembly job.

Environment

Release:
Component: APAS