Executing EZTCOM with NEWFUNC set to NO executes as NEWFUNC set to YES.

book

Article ID: 53082

calendar_today

Updated On:

Products

CA PanAudit Plus CA Easytrieve Report Generator CA PAN/SQL CA Endevor Software Change Manager (SCM) CA Endevor Software Change Manager - Natural Integration (SCM) CA Endevor Software Change Manager - ECLIPSE Plugin (SCM) CA Endevor Software Change Manager - Enterprise Workbench (SCM)

Issue/Introduction

Description:

When the R11.x option file has NEWFUNC set to No and EZTCOM is being executed, statistics do not show that the program is run in compatibility mode.

Solution:

Executing EZT or EZTCOM invokes the new, strictly r11.x modules.
Executing EZTPA00, contains the logic to determine whether the 6.4 or r11.x compiler is called based on the NEWFUNC option.
Executing EZT or EZTCOM will always result as a hard-coded EZT 11.x job. It takes NEWFUNC out of the picture.

Please Note: It is best to execute EZTPA00 as in past releases of Easytrieve. instead of EZT or EZTCOM. Future releases may not have the functionality included to execute EZT or EZTCOM.

Environment

Release: EDBMSU00200-11.5-Easytrieve-Report Generator-Option for DB2-MSU
Component: