Is IMBED needed in the VISION:Inform 4.0 installation job SMPJOB01?
Solution:
The SMPJOB01 member of the SMPCNTL installation PDS delivered with VISION:Inform 4.0 allocates the SMP/E CSI.
If running Workload Automation to perform a JCL Check, a severity 8 error may be generated regarding the IMBED parameter at the index level of the VSAM file allocation:
CAY6037E UNKNOWN KEYWORD "IMBED" SPECIFIED IN OPERAND OF "INDEX"
DEFINE CLUSTER (NAME(INFORM.R40.CSI) -
FREESPACE(10,5) -
KEYS(24 0) -
RECORDSIZE(24 143) -
SHAREOPTIONS(2 3) -
VOLUMES(VOLSER) -
UNIQUE) -
DATA(NAME(INFORM.R40.CSI.DATA) -
CONTROLINTERVALSIZE(4096) -
CYLINDERS(60 20)) -
INDEX(NAME(INFORM.R40.CSI.INDEX) -
CYLINDERS(5 5) -
IMBED)
According to the IBM documentation, "IMBED|NOIMBED is no longer supported; if it is specified, it will be ignored and no message will be issued".
While errors only occur if running a JCL check, IMBED is obsolete and can safely be deleted.