Description:
After installing CA Top Secret 14.0 using CA MSM (CA Mainframe Software Manager), the following error is received when IPLing:
CAS9115I - INPUT: PRODUCT(CAIRIM) VERSION(S910) INIT(S910INIT) IEF196I CAS9115I - INPUT: PRODUCT(CAIRIM) VERSION(S910) INIT(S910INIT ) *CAS9025A - NO SECURITY SYSTEM AVAILABLE IEF196I CAS9025A - NO SECURITY SYSTEM AVAILABLE R 55,TSS *55 CAS9026A - REPLY WITH SECURITY SYSTEM, "ACF2", "TSS", "RACF" OR "N" TO CANCEL IEF196I CAS9026A - REPLY WITH SECURITY SYSTEM, "ACF2", "TSS", "RACF" OR IEF196I "N" TO CANCEL IEE600I REPLY TO 55 IS;TSS CAS9023E - CAISSF INITIALIZATION ERROR - ROUTINES MISSING OR ALREADY PRESENT IEF196I CAS9023E - CAISSF INITIALIZATION ERROR - ROUTINES MISSING OR IEF196I ALREADY PRESENT CAS9140E - INIT ERROR: CAIRIM VER S910, INIT ROUTINE RC=0008 IEF196I CAS9140E - INIT ERROR: CAIRIM VER S910, INIT IEF196I ROUTINE RC=0008 CAS9115I - INPUT: PRODUCT(CA-ADAPTER-CMP) VERSION(YD53) INIT(YD53INIT )
Solution:
These errors are most likely the result of installing CA Top Secret 14.0 selecting PDS/E datasets for the CAILPA library.
LPA type libraries cannot be PDSE libraries. This is not a CA Top Secret restriction, but a z/OS one.
CA Top Secret needs to be reinstalled with CA MSM using PDS libraries.