CA 1 Tape Management CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options Compress Data Compression for MVS Compress Data Compression for Fujitsu Datacom DATACOM - AD CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware

Issue/Introduction

Description:

If the CAS9 job fails with the error, CAS9105E - INITIALIZATION ERROR - DYNAMIC PRODUCT INITIALIZATION ABORTED, the likely cause is that the common loadlib (CAILIB) is defined as a PDS/E. The current release of CAIRIM (r1.0) does not support PDS/E format load libraries. Support for PDS/E will be available in the next CAIRIM release.

Solution:

If the common loadlib (i.e. CAILIB) is defined as a PDS/E, you will need to:

  1. Change the CA Common Services CAILIB dataset organization from PDS/E to PDS.

  2. If necessary, change the //STEPLIB DD in the CAS9 JCL to reference the correct dataset name.

  3. Re-run the CAS9 job.