Execution of CAS9 (CAIRIM) job fails with error: CAS9105E - INITIALIZATION ERROR - DYNAMIC PRODUCT INITIALIZATION ABORTED.

book

Article ID: 52314

calendar_today

Updated On:

Products

CA 1 Tape Management CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options CA Compress Data Compression for MVS CA Compress Data Compression for Fujitsu CA Datacom - DB CA Datacom CA Datacom - AD CA Datacom - Server CA CIS CA Common Services for z/OS CA 90s Services CA Database Management Solutions for DB2 for z/OS CA Common Product Services Component CA Common Services CA ecoMeter Server Component FOC CA Easytrieve Report Generator for Common Services CA Infocai Maintenance CA IPC Unicenter CA-JCLCheck Common Component CA Mainframe VM Product Manager CA Chorus Software Manager CA On Demand Portal CA Service Desk Manager - Unified Self Service CA PAM Client for Linux for zSeries CA Mainframe Connector for Linux on System z CA Graphical Management Interface CA Web Administrator for Top Secret CA CA- Xpertware CA Datacom/AD

Issue/Introduction

Description:

If the CAS9 job fails with the error, CAS9105E - INITIALIZATION ERROR - DYNAMIC PRODUCT INITIALIZATION ABORTED, the likely cause is that the common loadlib (CAILIB) is defined as a PDS/E. The current release of CAIRIM (r1.0) does not support PDS/E format load libraries. Support for PDS/E will be available in the next CAIRIM release.

Solution:

If the common loadlib (i.e. CAILIB) is defined as a PDS/E, you will need to:

  1. Change the CA Common Services CAILIB dataset organization from PDS/E to PDS.

  2. If necessary, change the //STEPLIB DD in the CAS9 JCL to reference the correct dataset name.

  3. Re-run the CAS9 job.

Environment

Release:
Component: CAIRIM