AFFECTED SYSTEMS: Octel 250/350
DESCRIPTION: Beginning in December 2000, a 3COM/US Robotics 56K fax modem is being shipped with the Octel 250. Previously, a Boca Research 33.6-Kbps modem was provided. The US Robotics modem can also be used with the Octel 350 message server.
Make sure you set the dip switch settings to the following:
Dip switch settings
Switch 1 = On
Switch 2 = Off (default)
Switch 3 = Off
Switch 4 = On
Switch 5 = Off
Switch 6 = Off (default)
Switch 7 = Off (default)
Switch 8 = On (default)
When initializing the modem, use the following initialization string:
ATE0Q1&C1&D0S0=1&N6&K0Y0&W0
Although the current Peripheral Equipment Manual (part number 101-1386-002) does not refer to the US Robotics modem specifically, it can be used as a reference if further assistance is needed.
When ordering the 3COM/US Robotics 56K fax modem, use the following Comcode: 408430403.