eHealth cluster environment:: Unable to connect to 'port 5050' (Legacy KB ID CNC TS33164 )
search cancel

eHealth cluster environment:: Unable to connect to 'port 5050' (Legacy KB ID CNC TS33164 )

book

Article ID: 52031

calendar_today

Updated On:

Products

CA eHealth

Issue/Introduction

Some times, the above error can be  resolved by setting the NH_REPL_MSG_TIMEOUT value to 600 on both the Backend Pollers and Report Front End Console systems

Related Issues/Questions:
eHealth cluster environment:: Unable to connect to 'port 5050'
C:\Documents and Settings\ehealth>nhSynchronize -cluster -checkContext

   Cluster Sync initiated:

    Synchronizing objects of type element ........... FAIL 
    Synchronizing objects of type group ........... FAIL 
    Synchronizing objects of type groupSection ........... FAIL 
    Synchronizing objects of type groupList ........... FAIL 
    Synchronizing objects of type groupListContents ........... FAIL 
    Synchronizing objects of type serviceProfile ........... FAIL

   Error: Unable to connect to 'port 5050, host <Host1> (Error 0). 
   Error: Timed out waiting for request 'RmsGetDataReply' from host <host2>.

Problem Environment:
eHealth


(Legacy KB ID CNC TS33164 )

Environment

Release: LHBASC99000-6.2-eHealth-Live Health Upgrade Elements
Component: