How to configure Spectrum to automatically clear an alarm after a specified amount of time.
search cancel

How to configure Spectrum to automatically clear an alarm after a specified amount of time.

book

Article ID: 51870

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

How to configure Spectrum to automatically clear an alarm after a specified amount of time.

Environment

Release: Any
Component:

Resolution

1. Log into OneClick as an ADMIN user

2. Find and select the VNM model

3. Click on the Information tab in the Component Detail panel

4. Find and expand the Alarm Management subview



Age Out Residual Alarms Only

Specifies whether only residual old alarms are cleared. Residual alarms are alarms that existed before SpectroSERVER restart and have not been reverified. If enabled, CA Spectrum clears only residual alarms that are based on the Alarm Age Out timer setting.

Default: Yes

Alarm Age-Out Time (hours)

Defines how long an alarm can exist in CA Spectrum. Once an alarm has existed for the number of hours that you specify by this attribute, it is a candidate for automatic removal. To disable this functionality, set this attribute to zero (0).

Every hour, CA Spectrum checks the status of all alarms in the landscape and uses this option to determine whether alarms are cleared. Therefore, an alarm is not removed at the precise moment when its existence time has exceeded the time-out. An alarm can be, at most, an hour “overdue.” 
You cannot age out non-user clearable alarms. The system functionality that generates such alarms, clears them. Maintenance Mode, Device Has Stopped Responding, and Management Agent Lost are the non-user clearable alarms.

NOTE: An aged out alarm which is cleared displays the "System.Alarm_AgeOut" value in its corresponding "Cleared By" column under "Cleared Alarms History" tab. The corresponding cleared event also displays this value in its "Cleared By" column under Events tab.

Age Out Alarm Cause IDs Usage:

Specifies behavior performed on the alarms with the cause IDs specified when the Alarm Age-Out timer expires.

Age Out Alarm Cause IDs:

Specifies a set of alarm cause IDs which may be cleared/not cleared based on usage setting. If no cause IDs are set, then Alarm Age-Out may apply to any clearable Alarm which exceeds the age out time.

Additional Information

Reference the "Alarm Management Subview" section of the documentation for more information.