Abend S0C4 in Sysview for Db2 NSIGHTDC NADCFUNM upon DC startup caused by invalid PCSSID
book
Article ID: 51732
calendar_today
Updated On:
Products
SYSVIEW Performance Management Option for DB2 for z/OS
Issue/Introduction
The startup of the Sysview for Db2 for z/OS (IDB2) Data Collector abends immediately with a S0C4 in NSIGHTDC module NADCFUNM. The Data Collector terminates immediately.
Resolution
The PCSSID stated in the PC task and in the hlq.SOURCE members IDDCPRMS/IDUIPRMS cannot have the same name as the Db2 subsystem name.