Abend S0C4 in NSIGHTDC NADCFUNM upon DC startup caused by invalid PCSSID
search cancel

Abend S0C4 in NSIGHTDC NADCFUNM upon DC startup caused by invalid PCSSID

book

Article ID: 51732

calendar_today

Updated On:

Products

RC Compare for DB2 for z/OS Bind Analyzer for DB2 for z/OS SQL-Ease for DB2 for z/OS SYSVIEW Performance Management Option for DB2 for z/OS Plan Analyzer for DB2 for z/OS Subsystem Analyzer for DB2 for z/OS Database Analyzer for DB2 for z/OS Fast Unload for DB2 for z/OS Fast Check for DB2 for z/OS Fast Index for DB2 for z/OS Rapid Reorg for DB2 for z/OS

Issue/Introduction

Description:

The startup of the Data Collector abends immediately with a S0C4 in NSIGHTDC module NADCFUNM. The Data Collector terminates immediately.

Solution:

The PCSSID stated in the PC task, and in the .SOURCE members IDDCPRMS/IDUIPRMS can not have the same name as the DB2 subsystem name.

Environment

Release:
Component: IDB2