How to create a Normal Alarm when pingable device is back contactable.

book

Article ID: 51559

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

Description

You can configure CA SPECTRUM to notify you when a fault device resumes its back-to-normal condition. This solution uses Event Configuration Editor to provide an example of how to configure CA SPECTRUM to generate a Normal Alarm when Pingable device is back contactable.

Solution

The solution is made up of two major steps:

  1. Raise Normal Alarm when Pingable device is back contactable
  2. Clear Normal Alarm when Pingable device is not contactable

To Raise Normal Alarm when Pingable device is back contactable

  1. Launch ECEditor and filter for event 0x00010301.
  2. On the Alarms tab, Generated Alarm section, select Normal as Severity and fill in fields for Symptoms, Probable Causes, and Recommended Actions.


<Please see attached file for image>

Figure 1

  • Select the tab Event Options and click [Override...] button.
  • Select Pingable in the Model Type dialog and click [OK].
  • Select checkbox Store Event in Historical Database if you want the event to be stored in the database.


<Please see attached file for image>

Figure 2

  • Select¬†from the menu bar File, Save All.
  • To Clear Normal Alarm when Pingable device is not contactable

    1. Launch ECEditor and filter for event 0x00010d35.
    2. Click the triangle with '+' sign icon in the "Cleared Alarm(s)" box.
      The dialog Add Cleared Alarm dialog will appear.
    3. Click [Browse ...] button and select for alarm 0x00010301.


<Please see attached file for image>

Figure 3

  • From the menu bar, select File,¬†Save All.


<Please see attached file for image>