What needs to happen when CA Jobtrac Job Management issues the message 'TRAC096A SYSOUT CAPTURE FULL. ENTER ACTION TO BE TAKEN'?
search cancel

What needs to happen when CA Jobtrac Job Management issues the message 'TRAC096A SYSOUT CAPTURE FULL. ENTER ACTION TO BE TAKEN'?

book

Article ID: 51517

calendar_today

Updated On:

Products

Jobtrac

Issue/Introduction

What actions to take when  Jobtrac issues the following message:

 
'TRAC096A SYSOUT CAPTURE FULL. ENTER ACTION TO BE TAKEN'

 

Environment

Release:
Component: JOBTRC

Resolution

If this message appears, you have three reply options: 'IGN' to ignore the error and go to the next job; reply 'ARCH' to initiate capture archive processing; reply 'ABEND' to abend the CA Jobtrac JM writer task. ARCH is the suggested reply. This unloads and archives aged sysouts, providing room for more additions. If the message continues to appear after aged sysouts have been archive, then you will need to enlarged your CA Jobtrac JM Capture file. '

 

Information on doing this can be found in the CA Jobtrac Reports, maintenance and Recovery Guide, Chapter 4, recovery section on "Moving the Sysout Capture File'.