Export of data from the Workstation is impacted by "Data limited to 100 matching metrics" in the data viewer
search cancel

Export of data from the Workstation is impacted by "Data limited to 100 matching metrics" in the data viewer

book

Article ID: 5140

calendar_today

Updated On:

Products

CA Application Performance Management Agent (APM / Wily / Introscope) INTROSCOPE

Issue/Introduction

A Workstation data viewer for a metric grouping shows message "Data limited to 100 matching metrics". This is also impacting the export of all the required data i.e. data is limited to only 100 metrics.

Environment

CA Application Performance Management 10.7

Cause

The default workstation data viewer limit is 100 metrics and is designed to prevent a workstation performance problem.

It can be increased by adding hidden property introscope.enterprisemanager.workstation.viewerMetricLimit to the IntroscopeEnterpriseManager.properties file. 

However care should be taken to avoid any negative Workstation performance impact. 

Resolution

The safer option is to use the Command Line Workstation (CLW) to export all the required agent metric data

APM Command-Line Workstation > CLW Command Reference > Extract Persistent Data from SmartStor (Within a Time Range)

Additional Information

To run CLW you just need a local copy of the CLWorkstation.jar file and you can run it to connect to a remote Enterprise Manager server

APM Command-Line Workstation