RC/Secure : PT743E module is not an APF authorized library module.
search cancel

RC/Secure : PT743E module is not an APF authorized library module.

book

Article ID: 51140

calendar_today

Updated On:

Products

RC/Secure for DB2 for z/OS

Issue/Introduction

In RC/Secure, when performing a recover dropped object security on a large amount of objects and then submitting on-line, the following error occurred:

*** PT743E: Module is NOT an APF Authorized Library Module ***  
*** A unrecoverable processing error has occurred. ***  

 

Environment

Release: R20
Component: RCSDB2

Resolution

Ensure the steps defined under the  authorized-library-requirements  are implemented.

Also, check the bottom of the online report for the following error:

*** RS533 GETMAINED AREA EXHAUSTED ***  