U11NDAPR-01 U11NDACL RC=0028 occurs in batch job(s) in Workload Automation Restart Options for z/OS Schedulers r11.0. What does this mean?
When U11NDAPR-01 U11NDACL RC=0028 occurs, this normally indicates that an older version of U1122SVC was loaded.
Below is examples of the complete message that will appear in the joblog of the affected job(s):
U11NDAPR-01 U11NDACL RC=0028 ACTION=LOCNEXT TYPE=CSDKY 596 DATACOM RC= (000) CMD=REDKX KEY=CAL7jjjjjjjj_0000000C0000000C CALLER: U11RHF+0EFA (ASSEMBLED: 04/06/10 01.14) U11NDAPR-01 U11NDACL RC=0028 ACTION=GETNEXT TYPE=DSNKY 597 DATACOM RC= (000) CMD=REDKX KEY=CAL7jjjjjjjj_000000000000000000000000 CALLER: U11RHP+11E2 (ASSEMBLED: 04/06/10 01.16) U11NDAPR-01 U11NDACL RC=0028 ACTION=GET TYPE=STPKY 602 DATACOM RC= (000) CMD=REDKX KEY=CAL7jjjjjjjj_0000001C CALLER: U11TR1+0438 (ASSEMBLED: 04/01/10 19.05)
The RC=28 indicates that somehow an older version of the CA 11 SVC was loaded by CAIRIM. Please check the CAIRIM proc and ensure that module U1122SVC is found from the CA WA Restart Option r11.0 load library and not from a load library from a previous release.
Also the following DBAS command can be issued to verify the release of the U1122SVC module:
COMCHAR DISPLAY MOD=U1122SVC (where COMCHAR is the value in your config file)
The output will display the level of the U1122SVC module that was loaded by CAIRIM.
The action to take when this message occurs is to correct the CAIRIM proc using the r11.0 version of this load module, and then start CAIRIM with ",REINIT" in the parameter.