IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM NOT.DEFINED DID NOT 606SUCCEED FOR JOB SYSVIEW. RETURN CODE: 00000008 REASON CODE: 0000080BDIAG1: 00000008 DIAG2: 0000F801 DIAG3: 05030004 DIAG4: 05020010
search cancel

IXG231I IXGCONN REQUEST=CONNECT TO LOG STREAM NOT.DEFINED DID NOT 606SUCCEED FOR JOB SYSVIEW. RETURN CODE: 00000008 REASON CODE: 0000080BDIAG1: 00000008 DIAG2: 0000F801 DIAG3: 05030004 DIAG4: 05020010

book

Article ID: 50673

calendar_today

Updated On:

Products

CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services Datacom/AD CA ECOMETER SERVER COMPONENT FOC Easytrieve Report Generator for Common Services INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware Compress Data Compression for MVS Compress Data Compression for Fujitsu Cross Enterprise Application Performance Management (APM) SYSVIEW Performance Management NXBRIDGE - SYSVIEW/ENDEVOR

Issue/Introduction

Description:

Every 2 minutes, SYSVIEW is sending a number of these messages. The names of all the unused log streams which are not defined in the INST0040 and INST0046 have been put to 'NONE' in the appropriate parmlib members AUDIT, LGLOOKUP, MSQDATA.

Solution:

Put the correct logstream.name for the LOGSTREAM-PLOTLOG-NAME and the LOGSTREAM-XLOG-NAME in the SYSDATA parmlib member.

The PLOTLOG log stream contains historical plot data records created by the data collectors and is defined in the installation job INST0041.

If the plot data records should not be collected and the PLOTLOG log stream is not defined set the following options in the SYSDATA member:

LOG-PLOT-RECORDS          NO
LOGSTREAM-PLOTLOG-NAME    NONE 

The XLOG log stream contains exception records created by the IMS, MVS, TCP/IP and WebSphere MQ data collectors and is defined in the installation job INST0042.

If the exception records should not be collected and the XLOG log stream is not defined set the following options in the SYSDATA member :

LOG-XLOG-RECORDS        NO   
LOGSTREAM-XLOG-NAME     NONE  

Environment

Release:
Component: CA90S