Problem:

APPLY of fix RO20201 Fails with the following message:

GIM31901I SYSMOD RO20201 DOES NOT SPECIFY RO20031 ON THE PRE OR SUP OPERAND. RO20031 IS THE RMID FOR PRODXML CSA8500A THAT IS CURRENTLY INSTALLED.

 

Resolution:

CA InterTest for CICS release 8.5 SYSMOD RO20031 has been withdrawn and replaced by RO20201. If RO20031 is in APPLY status then RESTORE it and then APPLY RO20201.

 

Additional Information:

In the event that RO20031 was ACCEPTED it cannot be RESTORED you must edit RO20201 and add the SUP card below and then APPLY it.

SUP (RO20031)