CA RC/Migrator CA Endevor SCM Interface DB2 Administration CA RC Compare for DB2 for z/OS CA RC Extract for DB2 for z/OS CA RC/Query CA RC Secure for DB2 for z/OS CA RC Update for DB2 for z/OS CA Bind Analyzer for DB2 for z/OS CA Detector CA SQL-Ease for DB2 for z/OS CA Sysview Performance Management Option for DB2 for z/OS CA Database Detector for DB2 for z/OS CA Plan Analyzer for DB2 for z/OS CA Subsystem Analyzer for DB2 for z/OS CA Database Analyzer for DB2 for z/OS CA Fast Unload for DB2 for z/OS CA Fast Check for DB2 for z/OS CA Fast Index for DB2 for z/OS CA Fast Load for DB2 for z/OS CA Rapid Reorg for DB2 for z/OS

Issue/Introduction

Introduction: 

This document explains what causes a PSA0311 DATASTORE VALIDATION FAILED/VERSION INCOMPATABLE message.

Question: 

Why am I getting a PSA0311 DATASTORE VALIDATION FAILED/VERSION INCOMPATABLE message?

Environment:  

z/OS 1.11 and above.

Answer: 

The PSA0311 message occurs when a Datastore from a previous release (e.g. r14) is used to collect data in a newer release (e.g. r17). A new Datastore must be created for the new release. Afterwards, you can run the PSADSCPY member in your High.Level.CDBASRC library to copy the data from your Old Datastore into your new one.

Additional Information:

Starting with release 16, datastores created by release 15 & above can be used without having to run the PSADSCPY conversion job. However, once the datastore is viewed using the higher release, it can no longer be viewed by the older release unless it's appropriate Datastore Compatibility PTF is applied.

 

 

 

 