Common Services v14?Getting return code 12 on apply job with several linkedit errors.

book

Article ID: 49827

calendar_today

Updated On:

Products

CA 1 Tape Management CA 1 Tape Management - Copycat Utility CA 1 Tape Management - Add-On Options CA Compress Data Compression for MVS CA Compress Data Compression for Fujitsu CA Datacom CA DATACOM - AD CA CIS CA Common Services for z/OS CA 90s Services CA Database Management Solutions for DB2 for z/OS CA Common Product Services Component CA Common Services CA ecoMeter Server Component FOC CA Easytrieve Report Generator for Common Services CA Infocai Maintenance CA IPC Unicenter CA-JCLCheck Common Component CA Mainframe VM Product Manager CA Chorus Software Manager CA On Demand Portal CA Service Desk Manager - Unified Self Service CA PAM Client for Linux for zSeries CA Mainframe Connector for Linux on System z CA Graphical Management Interface CA Web Administrator for Top Secret CA CA- Xpertware CA Datacom/AD

Issue/Introduction

Description:

The installation of CA Common Services v14 will not complete successfully if CAICCI is being installed into the same SMP/E CSI where the previous release of CA Common Services and CAICCI is installed. The following snipit of linkedit messages will be generated and found in the SMP/e output.

GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD CAW4E00 FAILED FOR MODULE CAS9P6LS IN LMOD CAS9PDPM IN THE CAILIB LIBRARY.
              THE RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE. DATE 11.354 - TIME 10:42:14 - SEQUENCE NUMBER 000034 -
              SYSPRINT FILE SMP00051.
 GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD CAW4E00 FAILED FOR MODULE CAS9P6PS IN LMOD CAS9PDPM IN THE CAILIB LIBRARY.
              THE RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE. DATE 11.354 - TIME 10:42:14 - SEQUENCE NUMBER 000034 -
              SYSPRINT FILE SMP00051.
 GIM23912E ** LINK-EDIT PROCESSING FOR LOAD MODULE BUILD PROCESSING FAILED FOR MODULE CASNTXNT IN LMOD CAS9PDPM IN THE
              CAILIB LIBRARY. THE RETURN CODE (12) EXCEEDED THE ALLOWABLE VALUE. DATE 11.354 - TIME 10:42:14 - SEQUENCE 
              NUMBER 000034 - SYSPRINT FILE SMP00051.
 
BATCH EMULATOR  JOB(AW04APP ) STEP(APPLY1  ) PGM= IEWL
IEW2278I B352 INVOCATION PARAMETERS -  NCAL,LIST,LET,XREF,RENT,AC=1,AMODE=31,RMODE=24,COMPAT=PM3,CALL
IEW2322I 1220  1    INCLUDE SMP00030(CAS9P6LS)             CAW4E00       SEQ # 000031
IEW2322I 1220  2    INCLUDE SMP00030(CAS9P6PS)             CAW4E00
IEW2322I 1220  3    INCLUDE CW110LLD(CASNTXNT)             LMODBLD
IEW2322I 1220  4    INCLUDE SMPWRK3(CAS9PDPU)              LMODBLD
IEW2322I 1220  5    INCLUDE SMPWRK3(CAS9PSUS)              LMODBLD
IEW2322I 1220  6    INCLUDE SMPWRK3(CAS9P6US)              LMODBLD
IEW2322I 1220  7    ENTRY   CEESTART
IEW2322I 1220  8    NAME CAS9PDPM(R)                       MAX ACCEPTABLE RC=04
IEW2456E 9207 SYMBOL LINEDRVR UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL [email protected] UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL [email protected] UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL [email protected] UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL [email protected] UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL SECSOCSE UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL SECSOCRE UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL @ST00001 UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2456E 9207 SYMBOL @ST00002 UNRESOLVED.  MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.
IEW2606S 4B39 MODULE INCORPORATES VERSION 3 PROGRAM OBJECT FEATURES AND CANNOT BE SAVED IN LOAD MODULE FORMAT.

Solution:

Install CA Common Services v14 into a new SMP/E CSI.

The new release of CA Common Services must be installed into a new SMP/E environment. When installing CCI or any other FMID into an existing environment you will wind up with a merger of JCLIN information. This causes conflicts because new JCLIN does not replace old JCLIN.

Environment

Release:
Component: CCIMVS