Description:
A new install, upgrade, or switching from job to stc or backwards, the start of MSM job or STC fails with:
IEA822I COMPLETE TRANSACTION DUMP WRITTEN TO MSMTC.D032.T0704401.MSMTC
CEE3797I LANGUAGE ENVIRONMENT HAS DYNAMICALLY CREATED A DUMP.
IEA995I SYMPTOM DUMP OUTPUT
USER COMPLETION CODE=4093 REASON CODE=00000034
TIME=07.04.40 SEQ=01043 CPU=0000 ASID=0040
PSW AT TIME OF ERROR 078D1000 80008AAC ILC 2 INTC 0D
ACTIVE LOAD MODULE ADDRESS=00007188 OFFSET=00001924
NAME=CEEBINIT
DATA AT PSW 00008AA6 - 00181610 0A0DA7F4 001C1811
AR/GR 0: 00000000/84000000 1: 00000000/84000FFD
2: 00000000/00000034 3: 00000000/0FA2A300
4: 00000000/00000001 5: 00000000/0FA2BA08
6: 00000000/0FA2A300 7: 00000000/0FA2A7B0
8: 00000000/80000000 9: 00000000/07258FE6
A: 00000000/00000001 B: 00000000/800089D8
C: 00000000/0FA2BB48 D: 00000000/10268030
E: 00000000/87257DBA F: 00000002/00000034
END OF SYMPTOM DUMP
BPXP018I THREAD 0FF26D0000000000, IN PROCESS 67109210, ENDED
WITHOUT BEING UNDUBBED WITH COMPLETION CODE 84000FFD
, AND REASON CODE 00000034.
This abend generally indicates a setup problem with the user assigned to the MSMTC task.
A valid OMVS segment is required.
Please check with your security administrator to verify that an OMVS segment and the Home directory exists and is accessible.