Fast Unload execution abends with S806 for EDITPROC module.
search cancel

Fast Unload execution abends with S806 for EDITPROC module.

book

Article ID: 4929

calendar_today

Updated On:

Products

Fast Unload for DB2 for z/OS

Issue/Introduction

Executing Fast Unload for Db2 for z/OS (PFU) and encountering a S806 abend for an EDITPROC module:

CSV003I REQUESTED MODULE xxxxxxxx NOT FOUND                 
CSV028I ABEND806-04  JOBNAME=nnnnnnn  STEPNAME=xxxxxx   

  

SYSTEM COMPLETION CODE=806  REASON CODE=00000004 NO ACTIVE MODULE FOUND        
NAME=UNKNOWN                  

 

PFU0261I - TASK #02 -- MESSAGE DDNAME: PTIMSG02 -- MAX RC: S806  INCLUDES: 
                                              REASON CODE: 00000004

Resolution

Verify the SETUPxx member in use within hlq.CDBAPARM for the SSID entry has the correct LOADLIBS concatenation where EDITPROC module resides.