Datacom DATACOM - AD Ideal CIS COMMON SERVICES FOR Z/OS 90S SERVICES DATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OS COMMON PRODUCT SERVICES COMPONENT Common Services CA ECOMETER SERVER COMPONENT FOC EASYTRIEVE REPORT GENERATOR FOR COMMON SERVICES INFOCAI MAINTENANCE IPC UNICENTER JCLCHECK COMMON COMPONENT Mainframe VM Product Manager CHORUS SOFTWARE MANAGER CA ON DEMAND PORTAL CA Service Desk Manager - Unified Self Service PAM CLIENT FOR LINUX ON MAINFRAME MAINFRAME CONNECTOR FOR LINUX ON MAINFRAME GRAPHICAL MANAGEMENT INTERFACE WEB ADMINISTRATOR FOR TOP SECRET Xpertware

Issue/Introduction

Description:

User is getting IDADSVCS01E - Insufficient level of authorization trying to catalog a Dataview in CA Ideal. His authorization was changed from Ideal user to ADMIN/PRINT/DVW/IDEAL AUTHORITY but he is still getting the error message IDADSVCS01E -insufficient level of authorization trying to catalog a Dataview.

Solution:

The Ideal user's old authorizations is still in temp storage and will remain in temp storage until you MARK the user to PROD. If you have more than one region, You must issue the MARK user to PROD in every region (even though the user is already MARKED to PROD). It's the MARK PROD command that causes the USER PSA (temp storage queue) to be deleted and then when the user gets back in to CA IDEAL, it is rebuilt with the new authorizations.

Environment

Release:
Component: IDEAL