CA RC/Migrator CA Endevor SCM Interface DB2 Administration CA RC Compare for DB2 for z/OS CA RC Extract for DB2 for z/OS CA RC/Query CA RC Secure for DB2 for z/OS CA RC Update for DB2 for z/OS CA Bind Analyzer for DB2 for z/OS CA Detector CA SQL-Ease for DB2 for z/OS CA Sysview Performance Management Option for DB2 for z/OS CA Database Detector for DB2 for z/OS CA Plan Analyzer for DB2 for z/OS CA Subsystem Analyzer for DB2 for z/OS

Issue/Introduction

Description:

Why is the message PT733W: ACMID "XXXXXXXX" is undefined for DB2S (subsystem name) occurring when trying to enter products from the main menu?

Solution:

The PT733W will occur when the SETUPxx member contains the parameter ACMCHECK WARN. Set ACMCHECK to OFF to avoid the warning.

Alternate Catalog Mapping Check (ACMCHECK)
Indicates the processing to occur if an alternate catalog is not available when Alternate Catalog Mapping (ACM) is set to ON. Options are Off, Warn, and Fail.

Note: If an alternate catalog is not available, but a DEFAULT ACM table exists, the DEFAULT table is accessed instead of the DB2 catalog. For more information about ACMs, see the Value Pack Reference Guide.