IEW2465E error in link-edit processing for apply of r19 maintenance.
search cancel

IEW2465E error in link-edit processing for apply of r19 maintenance.

book

Article ID: 4888

calendar_today

Updated On:

Products

RC Compare for DB2 for z/OS Database Analyzer for DB2 for z/OS Fast Unload for DB2 for z/OS Fast Check for DB2 for z/OS Fast Index for DB2 for z/OS Rapid Reorg for DB2 for z/OS

Issue/Introduction

Apply of r19 maintenance fails return code 8 and issues error message for SYSMODs RO92347 and RO92931.

GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD RO92347 FAILED FOR MODULE OLCSELDF IN LMOD OLCSELDF IN THE CDBALOAD LIBRARY. THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 16.354 - TIME 16:55:55 - SEQUENCE NUMBER
000605 - SYSPRINT FILE SMP00027.

GIM23911E ** LINK-EDIT PROCESSING FOR SYSMOD RO92931 FAILED FOR MODULE PTABDBI IN LMOD OLCSELDF IN THE CDBALOAD LIBRARY.
THE RETURN CODE (08) EXCEEDED THE ALLOWABLE VALUE. DATE 16.354 - T IME 16:55:55 - SEQUENCE NUMBER 000605 - SYSPRINT FILE SMP00027.

The Binder report for sequence #000605 reports the following error:

IEW2456E 9207 SYMBOL _Nolock_on_output__Q3_3std7_EBCDIC8_LFS_OFF UNRESOLVED. MEMBER COULD NOT BE INCLUDED FROM THE DESIGNATED CALL LIBRARY.

 

Environment

Release:
Component: INS

Cause

The missing symbol reported in the IEW2456E error message should be located in SCEELIB(C128N).

Resolution

If symbol, '_Nolock_on_output__Q3_3std7_EBCDIC8_LFS_OFF', is missing from member C128N in the SCEELIB, then this suggests a z/OS compatibility issue. Only z/OS 2.1 and 2.2 are compatible with release r19. This error can occur with an older release of z/OS.