CA Datacom/DB Version 15.0 installation IVP job IVPNEW01 step DDRPT10 which executes PGM=DDUTILTY abends with S0C4 in module UNKNOWN:
SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011
TIME=11.43.22 SEQ=14327 CPU=0000 ASID=002A
PSW AT TIME OF ERROR 078D2000 00B002A0 ILC 2 INTC 11
NO ACTIVE MODULE FOUND
NAME=UNKNOWN
DATA AT PSW IS UNAVAILABLE AT THIS TIME
GR 0: 000095E8 1: 00006FF8
2: B8B002A0 3: 38B001C8
4: 00006FF8 5: 007F8588
6: 00006FF8 7: 00000000
8: 007FC780 9: 007D0CB0
A: B8B00000 B: 000099C0
C: 000077E8 D: 00012060
E: B8B040FE F: 38B002A0
END OF SYMPTOM DUMP
CA IPC Version 14.0 was not up to maintenance.
CA IPC 14.0 PTF RO89534 was the specific solution although the symptoms were different and more varied than RO89534 documented.
Since CA Datacom Datadictionary batch programs DDUTILTY and DDUPDATE use IPC batch, the PTF was required.
Note that the current CA IPC releases have equivalent solutions, as follows:
IPC 14.0 RO89534
IPC 15.0 RO89477
IPC 15.1 RO89915
In general, it is recommended that all CA IPC solutions be applied.
CA IPC READMEs say:
"All published solutions for CA IPC [version] should be applied after the SMP/E install and before executing the configuration steps. ..."
CA IPC 14.0 README RI30858
CA IPC 15.0 README RI64942
CA IPC 15.1 README RI88866