When trying to create a new job in WCC by pressing the 'Create' button in the Quick Edit tab, instead of getting a list of available object types, the following error is generated:
Error: E180011 Login failed using: User=ejmcommander Password=<hidden>.
The problem is caused by invalid user being specified in the WCC Credentials tab. Only the following user was present in the Credentials tab:
_MONITOR_:[email protected]
Add a valid user/password without the '_MONITOR_' prefix to the WCC Credentials tab for the affected WAAE server. For example:
The above user needs to be present in the autosys_secure [email protected] setting.
After adding and validating the user, the E180011 error should no longer be generated when trying to create a job in the WCC Quick Edit tab.
See also technical documents TEC1809413 and TEC1909323.