Error IPSD0003 can also occur on the NetMaster region when a packet trace is run outside of NetMaster and then it is
stopped. This would cause the NetMaster packet trace intercept to also stop--if the command to stop it was not specific.
We list the command to restart the packet trace intercept for the NetMaster region. The following command should be
executed on NetMaster CMD option to restart the packet trace intercept for the region:
SYSCMD VARY TCPIP,TCPIP,PKTTRACE,ON,LINKNAME=*,PROT=254
Note: The VARY command assumes that the TCP/IP proc name is TCPIP. Please see z/OS manual IP System Admin-
istrator's Commands for command details.
If this does not match your problem, please review these additional documents for a possible solution:
https://ca-broadcom.wolkenservicedesk.com/external/article?articleId=98157
https://ca-broadcom.wolkenservicedesk.com/external/article?articleId=72638
https://ca-broadcom.wolkenservicedesk.com/external/article?articleId=45396