Modules from the QA master file did not move to the Production master file.
Missing or incorrect QA load library.
Verify the loadlib for the QA level in the CCF chain definition is defined.
From the CCF Main Menu
1. Select Option 12 ADMIN SERVICES - LIB/CCF administrator services - press enter.
2. Select Option 11 LCDF - Library chain definition - press enter.
3. Select Option 2 MODIFY CHAIN - Modify library chain - press enter.
Enter * for a list of Library Chain - press enter.
CHAIN NUMBER ===> * (blank or asterisk for selection list)
From the "CHAIN SELECTION LIST" select the Chain Number - press enter.
NUMBER CHAIN DESCRIPTION CHAIN GROUP
00005 CHAIN FOR HISTORY APPLICATION HIST
S 00006 LEVEL I TESTING
Press Enter again
Press "END" to Continue for the CHAIN STRUCTURE
Press "END" to Continue for the CHAIN ATTRIBUTES
4. The ASSOCIATED FILES for the Chain will be displayed.
CHAIN NUMBER: 00006 CHAIN GROUP: *
DESCRIPTION: LEVEL I TESTING
TYPE: PRODUCTION FILE: LIBR.V44.LVL1.PRODMAST
OBJECT LIBRARY ===> LIBR.V44.LVL1.POBJECT
LOAD LIBRARY ===> LIBR.V44.LVL1.PRODLOAD
5. Verify the LOAD LIBRARY is defined, correct and it exits.