Sysview for Db2 Data Collector started task failed with SB78 abend and XNET failed with S0C4
search cancel

Sysview for Db2 Data Collector started task failed with SB78 abend and XNET failed with S0C4

book

Article ID: 4721

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

Sysview Performance Management Option for Db2 for z/OS (IDB2) Data Collector started task failed with SB78 abend.
At the same time the XNET started task failed with S0C4

IDB2 abend:
PXM0810 CA/XMANAGER RECOVERY IN PROGRESS 
PXM0811 PSW: 440C1000 813D064C LMOD: *UNKNOWN OFFSET: N/A ABEND: SB78
CCSR010E NMSPRMVC SB78 at 28BCC3B0 LMOD PXMTCTCC CSECT PXMTCTCC +0003B0
CCSR021I OWNER = CA Database Management R19.0 
CCSR022I MODULE = PXMTCTCC FMID = CINSJ00 RMID = RO84685 
CCSR060I BREAKING EVENT ADDRESS: 00000000 0994BEBC 
CCSR061I PSW: 44041000 80000000 00000000 013D064C 
CCSR062I ILC: 02 INTERRUPT CODE: 0D 
CCSR067I COMPLETION CODE SB78 REASON CODE 00004B30
CCSR064I DATA AT PSW 013D0646 : 00181610 0A0DE3E0 D0080024 

 

Xnet abend:
SYSTEM COMPLETION CODE=0C4 REASON CODE=00000011

Resolution

Restarting the XNET started task first and then the IDB2 Data Collector in that order resolved the problem.