Issue/Introduction
We are not getting alerts when a job is down that is required to be active in the mvs monitor definitions.
Environment
z/OS / MVS
Release: R16
Component: SYSVIEW
Cause
Three items are required for CA-SYSVIEW to monitor jobs that are required to be active.
Resolution
- SYSVIEW command STATES should have an entry definition for the job.
- SYSVIEW command SCHEDULE should have the entry for MVS-REQ-JOBS monitoring required jobs as active.
- SYSVIEW command MONITOR should have an entry for the job to be monitored that INCLUDEs it for monitoring.