SPC-OCC-10282: The event does not exist in the database.
search cancel

SPC-OCC-10282: The event does not exist in the database.

book

Article ID: 46382

calendar_today

Updated On:

Products

CA Spectrum DX NetOps

Issue/Introduction

The following error is seen when clicking on the "more" link in the Component Detail > Alarm Details tab in Spectrum OneClick:

SPC-OCC-10282: The event does not exist in the database.

Environment

Release: Any
Component:

Cause

The event associated with the alarm is not found in the Archive Manager (DDM) historical event database. The most common reasons:

1. The Archive Manager database was not available when the event was created. For example, the Archive Manager was down so events were logged locally to the SpectroSERVER database. By default, only 20,000 events are stored locally. If more get stored, the oldest events will be dropped. So this event was dropped while the Archive Manger was down.

2. The event associated with this alarm is not configured to be logged.

Resolution

Verify the event associated with the alarm is configured to the logged in the historical database.

In OneClick go to Tools -> Utilities -> Event Configuration

Find the event and verify the option "Store in historical database" is checked.

Additional Information

Please reference the "Event Configuration" section of the documentation for more information.