SDDC Manager Upgrade Precheck Fails with VpcFolderGprrRealizationObjectIdMigrationTask Error or Out of Memory (OOM)/Manager Memory Usage High alert triggered.
search cancel

SDDC Manager Upgrade Precheck Fails with VpcFolderGprrRealizationObjectIdMigrationTask Error or Out of Memory (OOM)/Manager Memory Usage High alert triggered.

book

Article ID: 463244

calendar_today

Updated On:

Products

VMware NSX VMware Cloud Foundation

Issue/Introduction

  • During the configuration precheck for a workload domain upgrade (e.g., from NSX 9.0.0.0 to 9.1.1.0), the SDDC Manager upgrade evaluation tool fails, blocking the upgrade process. The UI indicates the NSX cluster is stable, but the upgrade cannot proceed.

  • The precheck fails during the NSX Manager dry run with the following error:

    MP: <nsx-manager-name>: NSX Manager upgrade dry run failed. Do not proceed with the upgrade. Migrations that failed: Calculating effort for VpcFolderGprrRealizationObjectIdMigrationTask.



  • Additionally, a NSX Manager memory usage very high alarm alarm may be triggered in the NSX UI Alarm Dashboard.

Environment

VMware NSX
VMware Cloud Foundation

Cause

The failure is caused by an accumulation of orphaned Generic Policy Realized Resource (GPRR) entries, specifically TagBulkOperation intents, in the Corfu database. These orphaned records overwhelm the effort calculation process, leading to Out of Memory (OOM) exceptions when default heap memory limits are used.

Resolution

This is a known issue impacting VMware NSX. 

If you believe you have encountered this issue, and you require a workaround, open a support case with Broadcom Support and refer to this KB article.

For more information, see Creating and managing Broadcom support cases.