Why do we get VAN1555E error message?
search cancel

Why do we get VAN1555E error message?

book

Article ID: 46313

calendar_today

Updated On:

Products

Vantage Storage Resource Manager

Issue/Introduction

VAN1555E Object=HSMMLOG was not created because the task getmain limit of 010GB above the bar was hit.

Environment

Vantage

Cause

Installation of HSM IGDACSSC and/or ARCRDEXT exit 

Resolution

Increase the memory allowed above the bar using the VKGPARMS parameter MEMLIMTA.

Apply an early filter for DFSMSHSM via HSMTRIGS member in your PARMLIB. By default the HSMTRIGS member contains one empty line. If you want to filter DFSMSHSM messages and commands, remove the empty line.

If you choose to route all DFSMSHSM messages and commands to Vantage please note the following recommendations:

- Define an offload rule for LOGX and LOGY so data to be loaded by Vantage will be less

- Avoid DFSMSHSM scripts running concurrently

 

Additional Information:

The HSMTRIGS member from PARMLIB represents an early filter for DFSMSHSM messages and commands. If the HSMTRIGS member is not in your PARMLIB, copy the member from the **.CCTUSAMP library and customize it as needed.

The member copied from the CCTUSAMP library does not have any early filters. It does contain a blank line which means that all HSM messages will be routed to Vantage for analysis.

When the script HSMLOG is fired Vantage will load all data from LOGX, and afterwards apply the filter defined in the script.