Lost access to volume" alarm for the affected datastores./var/run/log/vobd.log and /var/run/log/vmkernel.log), "Path redundancy to storage device naa.######### degraded" are seen, but no "Permanent Device Loss (PDL)" nor "All paths Down (APD)" errors are seen./var/run/log/vobd.log, heartbeat.timedout may be seen, as the example below:In(14) vobd[2097707]: [vmfsCorrelator] 6367525864012us: [vob.vmfs.heartbeat.timedout] ########-########-####-############ Datastore_nameIn(14) vobd[2097707]: [vmfsCorrelator] 6367908844184us: [esx.problem.vmfs.heartbeat.timedout] ########-########-####-############ Datastore_name
VMware vCenter Server (All versions).
VMware vSphere ESXi (All versions).
This is expected behavior.
If specific paths are becoming degraded, expectedly as per the storage HA event, but no PDL nor APD events are seen, it means the VMware vSphere multipathing mechanisms are functioning as designed.
By default, vCenter Server is highly sensitive to storage hardware changes and heartbeat I/O delays. During a storage controller transition, there is typically a brief I/O pending window. If the ESXi host experiences a timeout on its datastore heartbeat during this window, vCenter immediately generates the "Lost access to volume" alarm before I/O fails over to the healthy paths.
Simultaneously, the ESXi host issues subsequent heartbeat reclaim operations to the datastore (approximately once per second) and the Native Multipathing Plugin (NMP) instantly pauses and fails over I/O to the surviving paths. Even though the ESXi host successfully recovers the heartbeat and prevents a true APD state, vCenter has already logged the initial heartbeat loss.
No corrective action is required on the ESXi hosts or vCenter Server, as this is expected behavior.
If the error message "Lost access to volume" is seen on vCenter and it's not during a planned Storage HA event, check:
"Host Connectivity Degraded in ESXi" warning in vCenter Server