Embedded Orchestrator integrations appear as user-deployed after upgrading from Aria Automation 8.18.x to VCF Automation 9.x
search cancel

Embedded Orchestrator integrations appear as user-deployed after upgrading from Aria Automation 8.18.x to VCF Automation 9.x

book

Article ID: 460244

calendar_today

Updated On:

Products

VCF Automation

Issue/Introduction

After upgrading an Aria Automation 8.18.x environment with sub-tenants, an embedded Orchestrator integration in a classic tenant appears as user-deployed in the VCF Automation UI. The corresponding vRO endpoint in the Provisioning database still refers to https://<subtenant>.<old-LB-FQDN>:443.

Environment

VCF Automation 9.x

Cause

The upgrade migration did not convert embedded Orchestrator endpoints belonging to sub-tenants to the internal https://embedded.orchestrator:443 address. These endpoints retain their tenant-prefixed Aria Automation load balancer hostname.

Resolution

The upgrade migration is fixed in VCF Automation 9.1.2 and later for direct upgrades from Aria Automation 8.18.x. For environments that already passed through an affected release, apply the workaround below.

Additional Information

This workaround applies to classic (VM Apps) tenants with embedded Orchestrator integrations in environments that:

  • Upgraded from Aria Automation 8.18.x to VCF Automation 9.0.x or 9.1.x through 9.1.1.
  • Followed that upgrade path and subsequently upgraded to 9.1.2 or later. The later upgrade does not repair these existing endpoint records.

Environments upgraded directly from Aria Automation 8.18.x to VCF Automation 9.1.2 or later are covered by the upgrade fix and should not apply this workaround

Workaround

Execute the provided inline script on a VCF Automation platform node, ensuring you replace the example FQDN with your specific original Aria Automation 8.18.x load balancer FQDN (<old-vra-lb-fqdn>). The script updates matching vRO endpoints in Provisioning service database.

Matching is case insensitive and requires the hostname pattern https://.:443

For example, input vra.example.com matches https://tenant1.vra.example.com:443, but does not match https://myvra.example.com:443 or https://external-vro.example.com:443.

Confirm that matching hostnames represent the old embedded Orchestrator integrations.

The script copies the embedded Orchestrator connection fields from an existing endpoint whose hostname is https://embedded.orchestrator:443, preserving other properties on each affected endpoint. When matching endpoints exist, exactly one source endpoint must exist. If there are zero or multiple source endpoints, the script stops without applying changes; contact Broadcom Support to determine the appropriate source.

Procedure

  • Take an on-demand backup of VCF Automation from VCF Operations before changing the database.
  •  Log in to a VCF Automation platform node and become root:

    ssh vmware-system-user@<VCFA-Platform-FQDN>
  sudo -i

  • Run the script below. You must replace <old-vra-lb-fqdn> at the end of the command with your specific old Aria Automation 8.18.x load balancer FQDN. Supply a DNS name only, without https://, a port, a path, or a trailing dot. Use the original load balancer name, without a tenant prefix. The script is decoded and piped straight into bash, so nothing is saved to disk on the node.

base64 -d <<< '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' | tar -xJO | bash -s -- <old-vra-lb-fqdn>

  • The output lists the affected endpoint IDs and old hostnames, followed by the updated hostnames, UPDATE <count>, and COMMIT. An SQL error aborts the transaction and the script exits unsuccessfully. UPDATE 0 means no matching endpoints were found; confirm the supplied old load balancer FQDN and the symptoms. After a successful repair, running the script again with the same FQDN updates zero rows.
  • Log in to the VCFA UI for each affected classic tenant. Navigate to Infrastructure > Integrations > Orchestrator and confirm that the integration appears as Embedded and is healthy. Run an appropriate Orchestrator workflow to confirm connectivity.

Recovery

If a committed change needs to be reverted, contact Broadcom Support and use the VCF Automation backup taken before this procedure.