After upgrading an Aria Automation 8.18.x environment with sub-tenants, an embedded Orchestrator integration in a classic tenant appears as user-deployed in the VCF Automation UI. The corresponding vRO endpoint in the Provisioning database still refers to https://<subtenant>.<old-LB-FQDN>:443.
VCF Automation 9.x
The upgrade migration did not convert embedded Orchestrator endpoints belonging to sub-tenants to the internal https://embedded.orchestrator:443 address. These endpoints retain their tenant-prefixed Aria Automation load balancer hostname.
The upgrade migration is fixed in VCF Automation 9.1.2 and later for direct upgrades from Aria Automation 8.18.x. For environments that already passed through an affected release, apply the workaround below.
This workaround applies to classic (VM Apps) tenants with embedded Orchestrator integrations in environments that:
Environments upgraded directly from Aria Automation 8.18.x to VCF Automation 9.1.2 or later are covered by the upgrade fix and should not apply this workaround
Execute the provided inline script on a VCF Automation platform node, ensuring you replace the example FQDN with your specific original Aria Automation 8.18.x load balancer FQDN (<old-vra-lb-fqdn>). The script updates matching vRO endpoints in Provisioning service database.
Matching is case insensitive and requires the hostname pattern https://.:443
For example, input vra.example.com matches https://tenant1.vra.example.com:443, but does not match https://myvra.example.com:443 or https://external-vro.example.com:443.
Confirm that matching hostnames represent the old embedded Orchestrator integrations.
The script copies the embedded Orchestrator connection fields from an existing endpoint whose hostname is https://embedded.orchestrator:443, preserving other properties on each affected endpoint. When matching endpoints exist, exactly one source endpoint must exist. If there are zero or multiple source endpoints, the script stops without applying changes; contact Broadcom Support to determine the appropriate source.
ssh vmware-system-user@<VCFA-Platform-FQDN> sudo -i
base64 -d <<< '/Td6WFoAAAFpIt42BMDCDYBQIQEcAAAAAAAAANna91zgJ/8Gul0AMxpLcv4NU4ZIK8GdY2R3uLDTfiGj9ceyZ7ji4Yx1cDRYND5ymXrAr5K2Yj4OBMOu9X5AfX48YbKYOfo37YoFEPUUSKrcb94R3aNyIYWIUogMP8EABTWLgzgO3JRG3cSo46i/p/HVIT0jYK79/nOlfwCzTEOmPRwqLZxL28FyF0Ck0MtHx/aWYpU9cWx3WzK19N7aQ3yLxHCQO5XQuYu5IzTtsd1udlCjBa4A82crrTui76Sw2OtTFqRbJO3FZfu55y+CkLoAgXAKV7EmU5ArGgme/GlvawJAYz3KspZLKv5DRMYiV7rAYfbYCrwOZVY5KnW3imQKqkK0QHhc5NwnCK5LYtwRspOJzdd4oGXSfnGtTW9NNsKESNrqPdivjsGW+2K7nyd9RtqtXHvK+SKKd9iRUFL9tNOcSo4KEZH+5i2QPU9/LXFrjQdzKZLhu2y8ZYdiHhlf+o0zHOjjGJhe1qLksXx3HuCQKXqDuTr3v9CfgY8oRWpwbp73gzAGpx+inymvk0r1BWGopdnhL9iiYdx1oh45+UbHcHRrTbEEz5X0KGlTMwordiikpukkBWojYWauQ724cElrWp51NXFOrXVAp6NVZL08FLJHG1AyjZjNwteOhz03Rff6+ZtPQCtCdRw7Zz8012XS4Fk9WfyGpcLTwHs/sBOWoGRh1l5oDhd1bFTpYuLz6bu0vHd9KdxYYxd77I0EOyj8eFq5kGGrimUYj95RjkSUuV4KRCNlKqkpeLg3jIDkBSdEBy0RRjlGd8aU7EKwNkeRWo0Ax0exnULCoP9abNsklzJSXEWRa+gARqY9P25YW/aMLq1LKtrtMyF0P5Jc4f0lx3p2n4xNRV5EGr9ThxGVjIACNpscKv5RscCKHWuMF9HtZVuAY3bP9Z2BrS/fESA59Lzq26SU7OqFX3lFA5HWbZG3I3JceoIIZbAjsA4bJ/PTc3WZ5m6XQMHY41hlPALpISaNy23aCoYTN9tB5Ru9gZsYW3nlXXkfXdJ3y0ppT+y8yWYLgv14MqQ2IzuesqIUbYy7SMmlP36sW9VsNyiWEL0Ye5zP/42nbD+ek14LnjiT1p58L86mnUA5n2xElmfLbAwdRMYQY9SaaTR7GEU35XM1ZOopStL2cXddP3qDlmkpEMifkrxLikFrN2Dy+5w38wL7BbTvyLmSHQuGV0jGtne8OXI6uViWhsfqC+j34yz40xMWZpUWMzmgKeKPj8vUWntaRV0+GSiRixxcPAK5Ht9owgltOOmkWtDXrT309CmlRX9yA1NJhYj9/9MgHnbc1vqSdfDgKk7XG6cQI51AqmpBfUd7nX2EkxdIjZj+pieeOpgY+XjLgBtECxMgn2BeL1X/M6H1WA0a2zFu3y2YNPe8sIfUjIwl5jHNjuZBwSoY0y2NpdObVlAQaEkCyEDul4DQQr6yw7HehBOlSSrlfEmN3c59UaGn8DDm9SZi6pksHUlLUDU4v6it5jH1EYF0/r4F6/Y5qI9zPUt3xST+qpM6EqTsDxDpT4LEHiL0TxRKWg59XLAwGk+u8kGT7/pLzXni+TJ1/CU3tOZ/7zyCLCFmSCkZOtatr5FHiYN+DXHYIP3khRNZRaaD703m8PoaHid2aIXJz1C9DpJkv6Auq4paYiWflmCrxLxAU4jrCWd8ZCxOqCpKP0neyqXp2YuLQWXf+Y2kLVMAiwjxWSofTixQhwlpkVCKgSW3hARBAclLHDsgEUjhrKyD60aWZ17gPH+cbea+2o/YtHrNdBf666GZnpiLDNFu1Lm/LaLBuYBqOHDyiOVeE4Y4Lsyq90nvzKlUNuB9GxgLiEJ3KYZ/z/CBzKhn1oEok+5HvQLGsO9mM4R4GSG3vUcf0ZhUDB26Gw2Bf7HO5jRFFV9icvlg46dboGQQLz1JkaD43/Yf16qwqkXfohfAdXzPvuZcDnWkGcezCJs3nlodDik2ZtvUCVx9rQaE6jxHlaGku93zdjFKbicB/S1EPI5Kr8sW9x91naFBlQU5qyjVR1R0qw7UXvVEWA5cC+Nbmb1q6+8qfUd6rHhAnww3GtoYrO3vsPLlHzKZAujku5h0nxdA9OiOfinDyoUFO7ptLKkmcS/XcFGqt4/FXzriVHRNTMvkrf1pDu1T2tWyjyOR5EeJFEdYOy9cYXiWGCFD46BSrPwbK1Z2z//48CnkuQHPiCAUD+QwQ5vawd7CeP+afEYuVcy5f64LGntr2QYMPgQiTYnLS3XfuB59NvfPfh/c0MExZGAb1PQuXHsyw+lMQUN2pFmOeaO1VdXXUs7aX3YTzOa7O6AAAAAAjToNTQAB2g2AUAAArreFCT4wDYsCAAAAAAFZWg==' | tar -xJO | bash -s -- <old-vra-lb-fqdn>
If a committed change needs to be reverted, contact Broadcom Support and use the VCF Automation backup taken before this procedure.