SDDC Manager Host Commissioning Fails with HOST_VSAN_HCL_VALIDATION_FAILURE Due to Uncertified SSDs
search cancel

SDDC Manager Host Commissioning Fails with HOST_VSAN_HCL_VALIDATION_FAILURE Due to Uncertified SSDs

book

Article ID: 459770

calendar_today

Updated On:

Products

VMware vSAN

Issue/Introduction

Issue/Introduction:

  • During host commissioning in VMware Cloud Foundation (VCF) SDDC Manager for vSAN clusters, the validation precheck fails at the host verification stage. 

  • The SDDC Manager UI displays the error:

  • Error seen on sos.tar.gz_extracted/vcf/sos<identifer>/sddc-<date>.tgz_extracted/var/log/vmware/vcf/operationsmanager/operationsmanager.log

2026-10-16T09:51:39.161Z DEBUG vcf_om 2057375 [sddcm@4413 traceId="0000000000000000" spanId="0000" threadId="om-exec-14" class="c.v.v.h.c.s.i.CommissionHostsValidator" method="lambda$validateHosts$4" line="240"] esxihost.local: HOST_VSAN_HCL_VALIDATION_FAILURE

  • SSDs used in the host enabled with iavmd drivers 

  vmhba   driver     driver version                  VID   DID   SVID  SDID  model
  -----   ------     --------------                  ---   ---   ----  ----  -------------------------------------------------
  vmhba0  iavmd      9.0.0.1100-7vmw.911.0.25714478  8086  28c0  8086  0000  Intel Corporation Intel Volume Management Device

Environment

VCF 9.1.1 

 

Cause

This issue occurs when Intel Volume Management Device (Intel VMD) is enabled in the host BIOS and ESXi kernel.

 

Resolution

Disable Intel IVMD on the impacted host's BIOS. 

  • HPE Servers: 
    1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration (RBSU) > Storage Options > NVM Express Options > Intel® NVMe > Intel® VMD Configuration Options.
    2. Select a setting.
      • Enabled

      • Disabled

    3. Save your setting.
  • Intel Servers: 
    1. Power on system and press F2 during startup > Advanced > PCI Configuration > Volume Management Device
    2. Use arrow keys to select each VMD that needs to be enabled or disabled (VMD Port 1x, VMD Port 2x and VMD Port 3x of each system Slot and PCIe SSDx can be enabled/disabled independently) press Enter key and select Enable or Disable
    3. Press F10 to exit saving the changes
  • Dell Servers 

    • Ensure the node you’re working on is placed in maintenance mode before proceeding
    • Once the host into maintenance mode, launch the remote console through iDRAC
    • Reboot the node and press F2 during POST to enter System Setup       

                                                                                                                                                            
    • Navigate through the following path: 
      System Setup → System BIOS Settings → NVMe Settings → VMD Mode
    • Set VMD Mode to Enabled                                                                                                                                                                                                               
    • Press ESC, choose Save Changes and Exit.
    • Allow the node to reboot completely.

Additional Information

If Intel VMD must remain enabled for OEM vendor-specific NVMe management, you can temporarily bypass HCL validation during commissioning by selecting the Skip HCL Compatibility Check option in the SDDC Manager UI wizard, or by setting "skipHclCompatibilityPrecheck": true in the host commissioning API payload.

Ref:

vSAN ESA Deployment: Override HCL Validation for Non-Certified Hardware