- 8-node vSAN ESA Cluster
- Customer wants to use Raid-5 storage policy only.
- vSAN Health check has warning of "vSAN default storage policy is optimized for cluster"
- Customer wants to clear the message
vSAN ESA 8.x
As there are 8 nodes in the vSAN ESA cluster, the recommended policy is Raid6.
There are 3 methods to clear the messages
1. Disable "Auto-Policy Management"
- Navigate to the target cluster, select Configure > vSAN > Services, locate the Storage section, and click Edit. Toggle "Auto-Policy Management" to Disabled, click Save, and retest the check under Monitor > Skyline Health.
2. Alternatively, if dual parity is acceptable, update the default storage policy directly to RAID-6 (FTT=2) to align with ESA recommendations.
3. Silence vSAN health check
https://knowledge.broadcom.com/external/article/314301/vsan-health-service-cluster-health-vsa.html