False-positive link down alerts in iDRAC on PowerEdge R770 with ESXi 9.1
search cancel

False-positive link down alerts in iDRAC on PowerEdge R770 with ESXi 9.1

book

Article ID: 458147

calendar_today

Updated On:

Products

VMware vSphere ESXi

Issue/Introduction

  • Customers running Dell PowerEdge R770 servers with VMware ESXi 9.1.0 may observe frequent (Network link is down) alerts within the iDRAC management interface.
  • These alerts often do not correspond to actual network connectivity loss or link-down events reported within vCenter or the ESX level. This article outlines the root cause and resolution for this behavior.

Environment

VMware ESXi 9.1.0

Cause

The issue stems from a firmware and driver compatibility mismatch between the Dell PowerEdge R770 hardware stack and VMware ESXi 9.1.0. Inconsistent communication between the hardware (iDRAC) and the operating system results in the iDRAC controller intermittently reporting false-positive link-down events.

Resolution

To resolve this issue, align the system firmware and network driver versions with the vendor-supported matrices.

  1. Verify the current firmware and driver versions on the ESXi host.
  2. Compare these versions against the Dell Hardware Compatibility List (HCL) for VMware ESXi 9.1.0.
  3. Download and apply the validated firmware and driver updates recommended by Dell for the R770.
  4. Monitor the iDRAC event logs after the update to ensure the alerts cease.
  5. If issues persist, perform a cold power cycle of the host to ensure the network interface controller reinitializes correctly.