Following a successful certificate replacement on both NSX and vCenter Server, the NSX Compute Manager encountered synchronization issue and entered into a DOWN and UNREGISTERED state.
Initial Remediation Attempt: Attempted to re-register the Compute Manager.
Outcome: Re-registration failed with error "7059: "Compute Manager is already registered with other NSX Manager."
Second Attempt: Executed the "Resolve" option on the initial error "7059: "Compute Manager is already registered with other NSX Manager." to clear the registration error.
Outcome: The 7059 error cleared, but immediately triggered a new error 90001 for certificate trust-related failure.
Error Received: Error 90001: "Trust cannot be enabled for compute manager."
Third Attempt: Applied the resolution steps outlined in Knowledge Base (KB) article 375169.
Outcome: The previous trust error transitioned to a new failure code.
Error Received: "OidcEndpoint is found but it is not suitable to be used while enabling trust on compute manager. Delete the existing OidcEndpoint and try enabling trust again on compute manager. ( Error code: 90018)."
root@<vCenter Name> [ ~ ]# openssl s_client -connect <vcenter-ip/fqdn>:443 </dev/null 2>/dev/null | openssl x509 -fingerprint -sha256 -noout -in /dev/stdinhttps://<nsx-manager-ip>/api/v1/trust-management/oidc-uris/vCenter Server: 8.0.3.0900 (Build: 25413364)
NSX-T: 4.1.2.4.0 (Build: 23786742)
The issue stems from incorrect compute manager thumbprint entry in the NSX Manager DB under "/api/v1/trust-management/oidc-uris".
Workaround :- Delete stale thumbprint entry and update correct thumbprint entry using API as shown below.
openssl s_client -connect <vcenter-ip/fqdn>:443 </dev/null 2>/dev/null | openssl x509 -fingerprint -sha256 -noout -in /dev/stdinGET https://<NSX-Manager-IP/FQDN>/api/v1/trust-management/oidc-uris/200 OK.oidc_uri": "https://<vCenter FQDN>/openidconnect/vsphere.local/.well-known/openid-configuration",
"thumbprint": "######################################",
"oidc_type": "vcenter",
"id": "##################################",DELETE https://<NSX-Manager-IP/FQDN>/api/v1/trust-management/oidc-uris/<enter-id-collected-from-Step-2>https://<NSX-Manager-IP/FQDN>/api/v1/trust-management/oidc-uris/{
"oidc_type": "As_per_output_of_GET_in_Step_2",
"oidc_uri": "As_per_output_of_GET_in_Step_2",
"thumbprint": "New_vcenter_thumbprint_as_per_output_in_Step_1"
}The response should be 201 Created.NSX UI --> System--> Fabric--> Compute managers--> click on alarms. Choose the error related alarm and click on resolve.If additional assistance is needed with troubleshooting, reach out to Broadcom support by creating a support case using the instructions at Creating and managing Broadcom support cases.