"Rescan Storage" or executing "esxcli storage core adapter rescan" does not discover or restore the missing targets and devices.VMware vSphere ESXi 8.x
During a Cisco UCS Fabric Interconnect upgrade or restart, the virtual Fibre Channel (vHBA) interface undergoes link-state re-initialization. Under certain timing conditions, the vHBA link experiences a rapid, sub-second link bounce (transitioning UP, dropping DOWN within milliseconds, and then returning to UP).
This target discrepancy occurs when the link drops while the ESXi SCSI mid-layer (ScsiScan) is mid-flight discovering storage array endpoints:
2026-09-19T08:14:07.418Z In(182) vmkernel: cpu2:####)nfnic: <1>: INFO: fnic_handle_link: 1171: fnic1: link up2026-09-19T08:14:07.418Z In(182) vmkernel: cpu2:####)nfnic: <1>: INFO: fnic_fdls_link_status_change: 104: fnic1: FDLS link status change link up:1, usefip:02026-09-19T08:14:07.691Z In(182) vmkernel: cpu86:####)nfnic: <1>: INFO: fdls_create_tport: 2282: FDLS create tport: fcid: #### wwpn: ####2026-09-19T08:14:07.691Z In(182) vmkernel: cpu86:####)nfnic: <1>: INFO: fdls_create_tport: 2282: FDLS create tport: fcid: #### wwpn: ####ScsiScan layer initiates SCSI inquiries to identify the LUNs behind those newly created transport ports, the link abruptly drops DOWN:2026-09-19T08:14:08.135Z In(182) vmkernel: cpu2:####)nfnic: <1>: INFO: fnic_fdls_link_status_change: 104: fnic1: FDLS link status change link up:0, usefip:0Because the link drops mid-handshake, ScsiScan commands fail with "No connection" errors on the paths assigned to those specific targets:
2026-09-19T08:14:08.137Z In(182) vmkernel: cpu45:####)ScsiScan: 532: Path 'vmhba0:##:##:##': Failed to read VPD Device id page: No connection2026-09-19T08:14:08.137Z In(182) vmkernel: cpu68:####)ScsiScan: 532: Path 'vmhba0:##:##:##': Failed to read VPD Device id page: No connection2026-09-19T08:14:08.137Z In(182) vmkernel: cpu67:####)ScsiScan: 603: Path 'vmhba0:##:##:##': Failed to read VPD Extended Inquiry page: No connection
2026-09-19T08:14:12.639Z In(182) vmkernel: cpu0:####)nfnic: <1>: INFO: fnic_handle_link: 1171: fnic1: link up2026-09-19T08:14:12.639Z In(182) vmkernel: cpu0:####)nfnic: <1>: INFO: fnic_fdls_link_status_change: 104: fnic1: FDLS link status change link up:1, usefip:0
Because the link drops mid-handshake, the HBA driver discards the pending discovery I/O, resulting in an H:0x1 (No Connection) SCSI status for the affected paths. When the link returns, the SCSI mid-layer does not trigger a re-scan of the specific aborted targets because the fabric state itself technically recovered, resulting in no new "fabric event" to notify the storage stack. Consequently, the host treats these paths as permanently disconnected until an administrative re-scan is performed.
Immediate Workaround (Online Recovery Without Host Reboot):
If a target or path mismatch occurs following a maintenance window, an online Fibre Channel reset can be issued to tear down and cleanly re-negotiate fabric login without rebooting the host:
esxcli storage san fc reset -A vmhba0esxcli storage core adapter rescan --adapter=vmhba0If the above doesn't resolve the issue, then proceed with the concerned ESXI host reboot to trigger the fabric login.