Upgrade Fails at vmsp_stage_precheck with "VCFMS-STAGE-COMPONENT-002" trying to upgrade VMware Cloud Foundation 9.1.0 to 9.1.1.
search cancel

Upgrade Fails at vmsp_stage_precheck with "VCFMS-STAGE-COMPONENT-002" trying to upgrade VMware Cloud Foundation 9.1.0 to 9.1.1.

book

Article ID: 457824

calendar_today

Updated On:

Products

VCF Operations/Automation (formerly VMware Aria Suite) VCF Automation

Issue/Introduction

Attempting to upgrade VMware Cloud Foundation (VCF) from 9.1.0 to 9.1.1.

The upgrade task fails during the staging or precheck phase with the following errors in the SDDC Manager UI:

ERROR: Internal error occurred. Failed to stage the VCF Component. Please retry the operation or contact support if the issue persists. [VCFMS-STAGE-COMPONENT-002]

ERROR: Step vmsp_stage_precheck failed. Reference Code: <Hex_Code>. Check logs for details.

Running: kubectl get pods -n vmsp-platform on the target VCF Operations node shows the staging pod in an error state.

Checking the logs for the specific staging pod (kubectl logs <pod-name> -n vmsp-platform) reveals the following sequence:

WARN: failed to update revision status: no revisions found
Error: context deadline exceeded
error: context deadline exceeded
ERROR : <task_id> Failed to stage package. Exit code: 1

Environment

VCF 9.1

VCF 9.1.1 

Cause

  • This issue occurs when the VCF 9.1.1 offline upgrade bundle (.tar file) uploaded to the SDDC Manager offline depot is corrupted or truncated (e.g., smaller than the officially published file size).
  • The internal SDDC Manager Fleet Controller caches this incomplete bundle. When the target node's Kubernetes staging pod attempts to download the payload, it expects the full file size. The transfer hangs mid-flight waiting for the missing data, eventually hitting the timeout limit and generating the context deadline exceeded error. This behavior mimics a network-level download interruption.
  • This issue can also occur if the latest bundle has been downloaded and you see a previous tar bundle when reviewing the staging pod logs.

Resolution

To resolve this issue, the corrupted bundle must be replaced and the Fleet Controller cache must be cleared so the orchestrator serves the correct payload.

Verify and replace the source file:

1. Compare the file size of your local VCF 9.1.1 offline bundle against the official file size listed on the Broadcom Support Portal.

2. If the file is truncated, delete it and download a fresh, fully intact .tar bundle. (If latest bundle is not present proceed to step 3)

3. Upload the verified bundle to the SDDC Manager offline depot.

4. Clear the Fleet Controller Cache:

5. Even after uploading the correct file, SDDC Manager will continue to serve the cached corrupted file to target nodes.

6. Follow the exact instructions and execute the cache-clearing script outlined in KB 444900 to purge the stale bundle from the Fleet Controller cache.

 

 

Additional Information

Verify payload delivery (Optional):

SSH into the target VCF Operations node.

Run a manual curl or wget command against the download URL provided by the Fleet Controller to confirm the file size being pulled matches the newly uploaded healthy bundle.

Retry the Upgrade:

Return to the SDDC Manager UI and re-run the VCF 9.1.1 update. The staging prechecks will now complete successfully.

 

Related Information
KB 448241: While this article specifically addresses VCF Automation (VCFA) rather than the core VCF 9.1.1 upgrade, it documents the identical context deadline exceeded Kubernetes pod timeout error. In both scenarios, the staging pod is failing to pull a massive payload due to either network termination (as in KB 448241) or a truncated source file.

KB 444900: Provides the required script and procedure for successfully clearing the Fleet Controller cache in VMware Cloud Foundation.