Troubleshooting NSX Edge Tunnel Degradation/Loss Due to Underlying Host Physical NIC Failure
search cancel

Troubleshooting NSX Edge Tunnel Degradation/Loss Due to Underlying Host Physical NIC Failure

book

Article ID: 457487

calendar_today

Updated On:

Products

VMware NSX

Issue/Introduction

 

  • NSX Edge node status shows as Degraded or Down in the NSX Manager UI.

  • Overlay TEP tunnels are partially or completely disconnected (e.g., fp-eth0 is UP, but fp-eth1 is DOWN).

  • VMs or services relying on the affected Edge node experience network degradation or loss of connectivity.

 

Environment

VMware NSX

Cause

A physical layer link failure occurred on the underlying ESXi host's physical NIC (vmnic) assigned to the Edge node's TEP/overlay traffic.

Resolution

 

  • Since this is a physical networking issue, please engage physical networking team to check:

    • Physical network patch cables and SFP/transceivers.

    • Upstream physical switch port status, VLAN configuration, and error logs.

  • Reseat or replace the cable/transceiver, or clear any port-security/err-disable states on the upstream switch.

  • Once physical link status recovers (Link Status: UP), the ESXi host and Edge node will automatically restore connectivity, and NSX Edge TEP tunnels will transition back to the UP / Healthy state.