SYSVIEW Logstreams require a minimum of two definition entries in order to be defined to the product.
The first entry is for writing data to the Logstream the second entry is to enable SYSVIEW to read the data from the Logstream.
The following Parmlib members must have the Logstream definitions contained in them in front of the )EOF that is in the member and makes the definitions available for writing data to the Logstreams.:
AUDIT, CICSLOGR, IMSLOGR, MQSDATA and SYSDATA
The Parmlib member LGLOOKUP must then be updated with the correct Logstream names in front of the )EOF in the member so that the definitions are available for SYSVIEW and enables reading of the data from the Logstreams.