Edge to Host Transport Node Overlay Tunnels Down Due to Blocked BFD/Geneve Ports (UDP 3784, 4784, 6081)
search cancel

Edge to Host Transport Node Overlay Tunnels Down Due to Blocked BFD/Geneve Ports (UDP 3784, 4784, 6081)

book

Article ID: 455157

calendar_today

Updated On:

Products

VMware NSX VMware vSphere ESXi

Issue/Introduction

  • NSX Transport Nodes and Transport Zones show a "Degraded" or "Unknown" status.
  • Overlay tunnels between Edge Transport Nodes and Host Transport Nodes are failing to establish and show a status of DOWN.
  • ICMP ping requests between Tunnel End Point (TEP) IP addresses succeed.
  • Bidirectional Forwarding Detection (BFD) control traffic fails to traverse bidirectionally between transport nodes.
  • Performing a packet capture on the ESXi host uplink shows BFD packets are sent but no return packets are received, the traffic is likely blocked by a physical network device.
    • pktcap-uw --uplink vmnic<X> --capture UplinkSndKernel,UplinkRcvKernel -o - | tcpdump-uw -enr -
    • Note: Filter the output for BFD traffic (UDP 3784) destined for the peer TEP IP.

 

Environment

VMware NSX

Cause

Required NSX overlay traffic ports are blocked by intermediate physical firewalls, routers, or switches sitting between the Host TEP and Edge TEP subnets.

Resolution

Ensure that the physical network and security infrastructure are configured to explicitly allow bidirectional UDP traffic for the following ports between all Host TEP and Edge TEP subnets:

  • UDP 6081: Geneve Encapsulation
  • UDP 3784: BFD Control 
  • UDP 3785: BFD Control (Additional port required for specific NSX deployments)
  • UDP 4784: BFD Echo