Unable to display Db2 metrics using the CE-APM or Sysview for DB2 interface.
The XNET logfile states:
Listener error: PXNWTSS function BIND - 13: Access denied
CE-APM, Sysview (DB2 option), Sysview Performance Management Option for Db2 for z/OS (IDB@), PTXNET (commonly known as XNET)
For some reason TCPIP would not allow the CE-APM or Sysview users the ability to bind to the port that was established for XNET.
The error: Listener error: PXNWTSS function BIND - 13: Access denied as seen in the XNET logfile is stating that TCPIP (for some undetermined reason)
will not allow a socket bind to XNET's port. Specifying a different port number in the XNET started task, Sysview's Db2 parmlib
member, and the Wily-Introscope's properties file, and then cycling the XNET and CE-APM started tasks corrected the access denied condition,
allowing the successful display of Db2 metrics.